Guardrail systems osha. Connect rails and posts with included slip-on fittings to quickly assemble a railing. Guardrail systems osha

 
 Connect rails and posts with included slip-on fittings to quickly assemble a railingGuardrail systems osha  Guardrails are a preferred means of protecting workers because the system does not rely on the worker to be trained to use, inspect, and wear a fall protection system

Guardrail Systems - 1926. for LORGUARD™. 501(b)(13), including guardrail systems, safety net systems, and personal fall arrest systems, must meet and be used in accordance with applicable requirements in 1926. Guardrail systems must be capable of withstanding at least 200 pounds of force applied within 2 inches of the top edge, in any direction and at any point along the edge, and without causing the top edge of the guardrail to deflect downward to a height less than 39 inches above the walking/working level. 1917. There are numerous hazards that can lead to serious injury in the construction industry. The top rail must be at least 42 inches in height (§1910. 501(b)(13), employers engaged in other specified work, such. For existing structures, survey the site before working and continually audit as work continues. (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. . Infrequent is defined as once a month or less, while. 28(b)(11)(ii) contains requirements for when handrails and stair rail systems must be present on certain flights. The guardrail face test is used to determine if a car is directed back onto a roadway when it meets the rail. Therefore, the guardrail system on the catch platform was not sufficient fall protection for the employees working on the walking/working surface of the structure. The employer has the option, in many instances, of providing a guardrail system or of having each employee use a personal fall arrest system. 500(a)(2)(vii). Factory Supply supplies, builds, designs and custom engineers OSHA and ANSI compliant rooftop guardrail systems for fall protection. -. Excep-tion: When the employer can dem-The prefab industrial handrail system ships quickly, and is long lasting, easy to install, and OSHA compliant. OSHA recognized that guardrail systems, safety net systems and personal fall arrest systems could pose feasibility problems during roofing work; therefore, the rule allows other choices of fall protection methods. 451 (g)(4) provides the requirements for guardrail systems. 814-623-8125 . Learn how to prevent falls and protect workers with. 814-623-8125 . Protect workers, pedestrians and equipment with FLS railing systems. Guardrail systems. The best case scenario, if a car is careening off the road, would be for that car to come to rest unhindered. If constructed of structural metal, the top rails to be angle iron of at least 2-inch by 2-inch by 1/4-inch angles or other metal shapes of equivalent bending strength; and the single midrail, where. Guardrail system can also be provided around the excavated area as a barrier. 500 (a) (2) or in § 1926. 500-1926. 453, A guardrail is, first and foremost, a safety barrier intended to shield a motorist who has left the roadway. x 4 in. Further, the non-penetrating design eliminates any holes in the roof and roof hatch. OSHA 1926. Its weighted, non-penetrating design makes it the perfect solution for permanent mounting and for temporary protection during roofing. 501. The end treatment tests are then conducted by having a vehicle strike the rail dead-on and also at an angle. (1) This section sets forth requirements for employers to provide fall protection systems. 1B, August 14, 1972. O. Interleaves with shingles. Spiral stairs must meet the. Fixed. 6300 W by NW Blvd #100, Houston, TX 77040. When workers are between 6’ and 15’ from the edge the same fall protection is required unless the work is “infrequent and temporary. The top edge height may exceed 45 inches (114 cm),Apr 16, 2018. 593. Section 1926. NextGen 3000 ™ Universal Guardrail meets the new OSHA Code 1910. There are several types of roof guardrails, each suited to different kinds of roofs and working environments. 501(b)(13), including guardrail systems, safety net systems, and personal fall arrest systems, must meet and be used in accordance with applicable requirements in 1926. Warning line system: A barrier erected on a roof to warn employees that they are approaching an unprotected roof side or edge, and which designates an area in which roofing work may take place without the use of guardrail, body belt, or safety net systems to protect employees in the area. 501(b)(13), employers engaged in other specified work, such. In addition, OSHA requires that fall protection be provided when working over dangerous equipment and machinery, regardless of the fall distance. OSHA requires that fall protection be provided at elevations of four feet in general industry workplaces, five feet in shipyards, six feet in. Handrails and the top rails of stair rail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in. 28; 1910. The three basic rail systems are based on the 2006 International Building Code (IBC 1013, “Guards”), the American Association of State Highway and Transportation Offi cials “AASHTO LRFD (Load and Resistance Factor Design) Bridge Design Specifications,” and the Occupational Safety and Health Administration rail system (OSHA, CFR 29, Part. To be considered compliant with OSHA’s regulations, the guardrail must stand 42 inches (plus or minus three inches) above the working or walking surface. The Guardian G-Rail system is a non-penetrating, temporary, contractor-grade railing. ”. 23 (b) General requirements for all ladders. 501(b)(12) states an explicit preference for use of conventional fall protection (fall restraint or fall arrest, safety nets, or guardrails) instead of alternative fall protection measures such as a CAZ or safety monitoring system. See WAC 296-880-40010 for other specific criteria for ramps, runways, and inclined walkways. Guardrails. 2. (d) Designated areas. hot rolled pickled electric weld tubing, free of sharp edges and snag points. This can be deployed around shipping pits, mezzanine perimeters, or a1926. Based on the relevant OSHA standards 1910. Product Details. This responds to your June 1, 1999, letter to the Occupational Safety and Health Administration (OSHA), requesting information on wire rope and Crosby clips used around the perimeter of buildings as a guardrail. Kee Guard Contractor safety railing is versatile, easy to assemble, and gives you an innovative approach to durable portable safety railing systems for roofs up to a 5 degree pitch. This section stipulates, in full detail, how guardrails and other safety barriers should be designed, installed, inspected, tested, and maintained in a manner that will prevent employees from falling. Safety yellow SafePro roof guardrails are available in 6’, 8’, and 10’ sections. , guardrail systems, safety net systems, or personal fall arrest systems) unless another provision in 29 CFR 1926. 28(b)(13) which mandates that when work is performed less than 15 feet (4. OSHA Incident Investigations. 1926. 502 (b) (1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1. OSHA Regulations. gov. 8 m) or more above lower levels shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system. 28 and 1910. Kee Guard is the industry leading modular, free-standing safety railing system that is not fixed directly to the roof membrane. 0 ˜ . 8 m) or more above lower levels, shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or shall work in a controlled access zone. 6 m) from the roof edge, the employer must ensure each employee is protected from falling by a guardrail system. Mounting Bases: Available as single and double post mounts. 500(g) because it recognized that the use of guardrail systems, safety net systems, and personal fall arrest systems could pose feasibility problems or greater hazard. These systems are offered in selections, such as non-penetrating, fixed and portable, to fit your passive fall protection system. 29(f) Handrails and. Unlike most other systems on the market that meet the federal OSHA 200 pound concentrated load test, our system meets federal OSHA AND the more stringent Cal OSHA 20 pound per linear foot test. If your facility's layout changes, the galvanized railing can expand. Positions for various roof pitches from 4/12 to 16/12. IMPORTANCE OF SAFETY RAILING SYSTEMS - APR 2023; ERECTASTEP CROSSOVER STAIRS - MAR 2023; INFORMATION ON FIXED LADDER LIFELINES - DEC 2022;(c) Safety net systems. Fall protection used to comply with 1926. 451(g)(4). Combine with SafePro weighted guardrail base plates (57-lb) for a simple, secure installation. 112 section. OSHA 29 CFR 1926. The other part that’s missed is where cross-braces exist. system, except those on single-point and two-point adjustable suspension scaffolds. Protection between top rail and floor, platform, runway, or stair treads, equivalent at least to that afforded by a standard intermediate rail (§1910. 0 ˜ . Top edge height of top rails, or equivalent guardrail system members, shall be ___ inches plus or minus 3 inches above the walking/working level. 502 - Infeasibility of 6 foot free fall limit. Generally, §1926. 1 m) plus or minus 3 inches (8 cm) above the walking/working level. Fall Protection Requirements. [29 CFR 1926. Do the spaces between the studs or the floor holes of the chase require fall protection (such as a guardrail system or cover) under §1926. The portable railing system can resist winds up to 70mph. 8 meters) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Apart from IBC, OSHA also has minimum strength requirements for guardrails. To add more layers of protection, screens, mesh, or balusters could be utilized in tandem with the guardrails. In addition, you submitted information regarding your freestanding guardrail system as well as a photograph of what appears to be a typical installation of the guardrail system. A-SAFE safety solutions for the automotive industry enhance site efficiency and protect your operations. Price $208. EHS Intelligence Environment Health Safety Leadership Standards Construction PPE Safety Technology Training & Engagement Emergency Management COVID-19 Crisis Industrial Hygiene. The top rail should be 42 inches in height plus or minus 3 inches above the walking/working level. Safety Yellow option in stock. This guardrail is meant to limit employees, contractors, or. Sincerely, The standard guardrail system features a toprail, intermediate (or mid) rail, and support posts. We hope that this answers your questions as to when a single bar gate may be used at access openings in guardrail. OSHA 1910. OSHA's fall protection standard for construction, 29 CFR Part 1926 Subpart M (Fall Protection) ("Standard"), as well as its related Directive Number STD 3-01. Toggle navigation. The 360 Hide-A-Rail Collapsible Guardrail System is a completely non-penetrating Safety Rail system that has been independently certified and tested to meet all OSHA Fall Protection regulations and standards for guardrail, sections 1910. Rail - safety yellow 404654G 10. 451(g)(1) • Guardrail height—The height of the toprail for The employer must ensure: 1910. This is only partially the case. Excep-tion: When the employer can dem-The prefab industrial handrail system ships quickly, and is long lasting, easy to install, and OSHA compliant. Request a quote today! Call us - 888-637-7872. 501(b)(13), workers engaged in residential construction six (6) feet or more above lower levels must be protected by conventional fall protection (in other words, guardrail systems, safety net systems, or personal fall arrest systems) or other fall protection measures allowed elsewhere in 1926. Do not attach fall arrest systems to guardrail systems or hoists. Rail - safety yellow 404977S 8. In that situation, the guardrail system must be raised the same height as the stilts. If you need a railing for your worksite, G-rail will get the job done!This includes a range of free-standing roof edge railing systems and rooftop guardrail for metal roofs. Mechanical equipment on roofs shall be used or stored only in areas where employees are protected by a warning line system, guardrail system, or personal fall arrest system. 5 inches (9 cm) as measured from the top edge of the toeboard to the level of the. The requirements for a guardrail system are stated in §1926. The lineup of accessories includes bases, brackets, bumpers, double sockets, end caps, end guards, gates, mesh, mounting brackets, post brackets, railing sleeves, sockets, spring posts, toe boards, connector tubes (male and female), clamping systems and more. system, except those on single-point and two-point adjustable suspension scaffolds. 501(b). Simply secure the portable guardrail using screw clamps wherever a rail is necessary and give your. The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. 502 (b) (1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1. Fall protection includes guardrail systems and personal fall arrest systems. The employer shall ensure that each connector has been provided training in the following areas: 1926. 29 (b) (3) (4) (5). (1) When the employer uses a designated area, the employer must ensure: (i) Employees remain within the designated area while work operations are underway; and (ii) The perimeter of the. Applicability of scaffold fall protection to guardrails near ladder access areas on scaffolds; toeboards across ladder access areas. OSHA Instruction STD 3-10. 451(g). 451(g)(4)(i), which reads in. Standard Number: 1926. • Guardrails are required on work surfaces where workers are at risk of falls greater than 6 feet. OSHA recognized these systems could pose feasibility problems during roofing work;. The standard in OSHA-compliant, modular, non-penetrating roof guardrail systems, SafePro safety railings are ideal for temporary or permanent rooftop applications. Some of the relevant provisions state: (vii) Each toprail or equivalent member of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal. According to OSHA 1917. General OSHA compliant guardrail systems for car tops, open hoistways or escalator wellways shall have a top rail 42 in. 23 includes requirements for ladders, where OSHA defines handrail requirements on platforms and how high safety railings must be. Systems integrate with existing ladders, equipment, and obstructions and provide durable OSHA and ANSI compliant fall protection for all standard rooftops including Membrane, Metal. 501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels shall be protected by guardrail systems, safety net systems or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection. It has been independently certified and tested to meet all OSHA Fall Protection regulations and standards for handrail & guardrail, sections 1910. , guardrail systems, safety net systems, or personal fall arrest systems) unless another provision in 29 CFR 1926. 500-1926. previously-installed stair rail systems by allowing the top rail of those systems to serve as a handrail when it is as low as 30 inches. The test subject shall be allowed to pick the most acceptable respirator. 28 (b) (13) (ii) When work is performed at least 6 feet (1. That original yellow railing represents over 35 years of industry experience, quality, and rigorous testing. Zhang@dot. Browse Construction Railing Systems. Secure your rooftop with our permanent freestanding roof railing. The scaffolding fall protection requirements are located in 1926. In 2018, OSHA conducted 40,993 State Plan Inspections. 502 (b)–(e) Fall Protection Systems Criteria and Practices (b) "Guardrail systems. Fall protection. 12) True or False: Ropes or lanyards used as part of a fall protection system must be made from synthetic fibers. Full-service FRP Solutions. 501 (b) (1)). In response to your request for other interpretations relevant to 1926. Guardrail requirements also include a top rail, intermediate rail and posts. Please review the full code for further information. Question #1: Does the OSHA scaffold standard for construction. com. Guard or cover any openings or holes immediately. The hazards addressed in this eTool * have been. Guardrail systems must be capable of withstanding at least 200 pounds of force applied within 2 inches of the top edge, in any direction and at any point along the edge, and without causing the top edge of the guardrail to deflect downward to a height less than 39 inches above the walking/working level. Workers engaged in residential construction 6 feet or more above lower levels must be protected by conventional fall protection (i. OSHA's fall protection standard for construction, 29 CFR Part 1926 Subpart M (Fall Protection) ("Standard"), as well as its related Directive Number STD 3-01. 29. OSHA compliant – under continuous self-test . 44 meters). Residential Construction – 29 CFR 1926. Unistrut Service Company offers modular rooftop guardrail systems that eliminate fall hazards and meet or exceed OSHA requirements. 501 (b) (1) through (b) (14), each employee on a walking/working surface 6 feet (1. The scaffolding fall protection requirements are located in §1926. Spatz The Graham Company One Penn Square West Philadelphia, PA 19102. 502(b)(3) requires railing systems meet a 200 pound concentrated load test. A single avoidable workplace incident is a potentially traumatic event for all personnel involved, meaning. Guardrail system criteria are contained in subpart M of this part. (link is external) Summary Report of 2021 MASH Virtual Roundtables. In combination with other safety hazards, safety prevention could save the lives of 468 workers per year. Guardrail systems can be used on many work surfaces, including rooftops, platforms, mezzanines,. Safety Net System : A horizontal or. These letters provide guidance to clarify the application of an established OSHA standard, policy, or procedure, but they may not, in themselves, establish or revise OSHA policy or procedure or interpret the OSH Act. ±3 in. 1. 502 (see appendix G). 3. All GuardRail columns are powder coat painted safety yellow. Safety and stability are ensured as this hand rail is made with rugged steel, coated with yellow thermosetting poly powder for protection against rust; Officially ANSI certified, CSA approved, and OSHA compliant; Purchase of this product includes two guard rails with gates and four gravity locks in the boxOSHA compliant instructions attached to each section. 8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, or personal fall arrest systems. It is acceptable that the intermediate rail is smaller than 2-inch by 2-inch by 3/8-inch angles. 501(b)(2)(ii) requires that employees on a walking/working surface 6 feet or more above a lower level shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system. Be aware of the wide rear swing radius. OSHA promulgated existing Sec. The employer must ensure guardrail systems meet the following requirements: (1) The top edge height of top rails, or equivalent guardrail system mem-bers, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walk-ing-working surface. , guardrail systems, safety net systems, orPersonal fall arrest or restraint systems must be used when there is a gap in the guardrail system. New build. Third Party Tested to Ensure Compliance and Safety. The SafetyRail 2000 Guardrail is an OSHA approved rooftop guardrail. When the employer can demonstrate that it is not feasible or creates a greater hazard to use guardrail, safety net, or personal fall protection systems on residential roofs, the employer must develop and implement a fall protection plan that meets the requirements of 29 CFR 1926. The freestanding design is non-penetrating, so there’s no danger of roof leaks. The agency has received numerous questions asking when handrails are required, and about the height requirements for handrails on stairs and stair rail systems. Inspect systems before each use for wear, damage, and other deterioration, and remove defective components from service. Guardrails are a stationary (or "fixed") system used to protect workers from falls when working at heights. In. Slope between 30° and 50° from the horizontal. Works with open edge guardrail system to form complete residential protection. The fall protection requirements for residential construction are set out in Subpart M at 29 CFR 1926. In general, fall protection is required when employees work on walking or working surfaces that are 6 feet or more above lower levels. Often rented by the General Contractor on large jobs, guardrails can also be rented by roofers, framers, concrete repair, HVAC, and steel erectors. , offers safety training, program implementation and management tailored to companies of all sizes. Where workers on a construction site are exposed to vertical drops of 6 feet or more, OSHA requires that employers provide fall protection in one of three ways before work begins: Placing guardrails around the hazard. 2 Guardrail Systems. Guardrails are a preferred means of protecting workers because the system does not rely on the worker to be trained to use, inspect, and wear a fall protection system. For more information on Guardrail Inspection, Maintenance, and Installation Information, please contact the Office of Safety, Aimee Zhang ( Aimee. Therefore, pursuant to paragraph 1926. The employers can choose whichever option they deem to fit their situation the best. Rail - galvanized 406930G 8. 753 (e). Safety monitoring systems [See §1926. Other evidence in the record, however, indicates that there are many portable and stand-alone fall protection systems available and in use today in both the rail and truck transportation industries, including overhead cable line systems, moveable stairs with railings, mobile access platforms with railings and/or safety cages and overhead. 0 ˜ . 501(b)(13), which requires fall protection (usually conventional fall protection, i. 451(g). 501(b)(1), even where there is a permanent guardrail with a 36-inch top rail that, pursuant to STD 01-01-010, is. The employer must ensure each. Clarification concerning fall protection and vertical walled trenches with depth of 6 feet or greater and use of controlled access zones. Self-rescue devices are not a fall protection system. to decrees falls using portable ladders, OSHA requires that ladder rungs are. The Safety Boot Guardrail System has been tested by an independent third party engineering firm as exceeding all applicable United States Federal OSHA guardrail regulations and requirements in order to assure compliance. Color. The best case scenario, if a car is careening off the road, would be for that car to come to rest unhindered. In sum, the plain language of §1926. There are numerous variations of standard guardrails, which must comply with OSHA standards. 751 - Definitions. 152 (f) (3) Category 1, 2, or 3 flammable liquids may be used only. 107 provide definitions for the pertinent terms. 501 (b) (2) (ii) Each employee on a walking/working surface 6 feet (1. The employer must ensure: ( i) Each employee on a scaffold is protected from falling in accordance 29 CFR part 1926, subpart L; and. A personal fall-arrest system is a system used to arrest an employee in a fall from a working level. It’s an OSHA compliant, permanent, and dependable safety guardrail barrier for a roof edge that is suitable for virtually any flat roof up to a 5° slope – keeping your workforce safe. Connectors working at heights over 15 and up to 30 feet must tie off with: At least one of the above. The GuardRail protective railing system comes in two styles: Single or Double Rail. Rail - galvanized 155278 Pin with bail, zinc plated Material 16 gauge Steel Top rail height 42” Mid-rail height 21” Outer diameter 1. 28 (b) that covers the responsibility for fall protection on working and walking surfaces. 21 (b) Definitions . (533 mm) high at centerline and toeboards. 501(b)(13), including guardrail systems, safety net systems, and personal fall arrest systems, must meet and be used in accordance with applicable requirements in 1926. Cover or guard an excavation that is not readily seen because of plant growth or other. 501 (b) (1) – each employee on a walking/working surface (horizontal or vertical) with an unprotected side or edge that is 6 feet or more above a lower level shall be protected from falling by use of guardrail systems, safety net systems, or personal fall arrest systems. Unlike most other systems on the market that meet the federal OSHA 200 pound concentrated load test, our system meets federal OSHA AND the more stringent Cal OSHA 20 pound per linear foot. This 200 pound load test is designed to stop an employee from a potentially fatal fall, as opposed to the IBC requirement that takes into account the idea that many people may be leaning on the railing at the same time. 29 (f) (1) (i) - Handrails are not less than 30 inches (76 cm) and not more than 38 inches (97 cm. The Occupational Safety and Health Administration’s (OSHA’s) construction scaffolding requirements and the 1996 revisions to 29 Code of Federal Regulations (CFR) 1926 Subpart L make working on or around scaffolding safer. 502 (b) For more than 35 years, RailGuard 200 rails and bases have been protecting the leading edge on rooftops. Handrails, stair rail systems, and guardrail systems are provided in accordance with §. oriented recommendations for the design, . Kee Walk with Guardrail meets OSHA compliance for guardrail systems: Capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2 inches (5 cm) of. Any of the above, Every. Must Withstand 200 Pounds. 29 (k) includes standards for “protection from falling objects”. 24) that consists of upright members which have connection points for. 500 1926. 1. Lifting equipment, such as ladder hoists, swing hoists, or truck-mounted cranes/conveyors, should be used wherever possible. People assume they are protected by “guardrails”. The fully reusable Safety Boot can be used for edge protection on most structures by building out an OSHA compliant guardrail system using job site tools and construction grade 2 in. guardrails, personal fall arrest systems, warning lines, and safety monitoring systems. Guardrail systems can be used on many work surfaces, including rooftops, platforms, mezzanines,. Despite its high fatality rate, construction can be a safe occupation when workers are aware of the hazards, and their employer implements an effective Safety and Health Program. 451 — 1926. Y. (3) Guardrails installed on or before May 26, 2011. Roof safety audits will help determine. 451, we enclose the following OSHA Instructions: 1. In this article, you’ll learn about the three types of OSHA-certified roof guardrails. 402335S 10. Similarly, OSHA 1926. Except as provided in § 1926. , guardrail systems, safety net systems, or personal fall arrest systems) for work 6 feet or more above lower levels, except where employers can. 502 (b. The maximum deflection of the top rail when a load. 6 feet (1. Lab testing has verified that hand tightening is sufficient to ensure that cross-members will not slip down the vertical tube when contacted with a 200-lb force, as. ing by the use of guardrail systems, safety net systems, or personal fall ar-rest systems. WIDTH ≥ 22” between railings. 1926. Safety Railing. The safety audit will highlight the hazards on the roof and guide the implementation of a guardrail system. (b) Guardrail systems. 1926. 29(b)(3) Guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2. 502(g)(l)(iv) requires that the control line be connected on each side to a guardrail system or wall. Workers engaged in residential construction 6 feet or more above lower levels must be protected by conventional fall protection (i. For stair rail systems installed on or after January 17, 2017, the top rail and handrail must be separate. Must Withstand 200 Pounds. Product Details. Bolted diagonal bridging means diagonal bridging that is bolted to a steel joist or joists. Collapsible guardrail enables rooftops to maintain desirable sightlines. Railings: 1-5/8 inch (41 mm) O. 3-1/2 in. Guardrail system: Used in fall protection to prevent accidents . 502(b)(3) requires that a guardrail structure be able to withstand a 200-lb force (such as a worker weighing 200 lbs or more falling into the guardrail). 1910. These employees should be protected by. Guardrail systems. 1-800-321-OSHA 1-800-321-6742 Federal Government White House; Benefits. 451 (b) (3) (ii) The maximum distance from the face for plastering and lathing operations shall be 18 inches (46 cm). 1, Safety Requirements for Workplace Walking/Working Surfaces and Their Access; Workplace Floor, Wall and Roof Openings; Stairs and Guardrail Systems. To prevent employees from being injured from falls, employers must: Guard every floor hole into which a worker can accidentally walk (using a railing and toe-board or a floor hole cover). Use a non-penetrating guardrail that doesn’t mount to any structure on your building. Please review the full code for further. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D–11 of this section). (2) The employer shall determine if the walking/working surfaces on which its employees are to work have the strength. (877) 723-3766. (c) Protection from falling objects. 502. (1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1. Other portable guardrail systems have larger spacing between each railing, and heavier bases weighing 100 pounds and more as compared to 57 lbs. 6 m) from the roof edge, the employer must ensure each employee is protected from falling. 00. Combine rails, posts, and gates to make a custom guardrail system. The example OSHA gives for when the guard rail system may need to exceed 45 inches is if workers are wearing stilts. Double guard rail columns are 43″ high. Connect rails and posts with included slip-on fittings to quickly assemble a railing. ( 13) Work on low-slope roofs. Safety Railing and Guardrail Systems. In accordance with 29 CFR § 1910. 451 (b) (4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). Unprotected sides and edges of stairway landings shall be provided with guardrail systems. ing by the use of guardrail systems, safety net systems, or personal fall ar-rest systems. OSHA 29 CFR 1910. Utilizing our standard 1¼” Accu-Fit rails – easily trimmed at corners and obstructions to fit your project needs – it features low-profile. Any working surface 4 feet or higher must be protected with guardrails on all sides at least 42" tall and have to withstand 200 pounds of force. The Guardian G-Rail system is a.